Welcome to Trinity Healthcare Nigeria

Mammography Machines

Siemens Mammomat 3000 Nova

We provide quality Refurbished Medical imaging Systems. We are refurbisher of excellent used Mammography systems. In refurbished Mammography systems, we provide Siemens Mammonat 3000 Nova/ 1000.

Technical Specifications
Generator
  • High-voltage wave form: Multipulse
  • Exposure voltage : 23kV to 35kV, adjustable in increments of 1kV
  • mAs range : Mo X-ray tube: 2mAs to 560 mAs (mAs-mode)up to 600mAs (AEC-mode)
  • Mo/W X-ray tube : 2mAs to 710 mAs (mAs-mode) up to 752 mAs (AEC-mode)
  • Exposure times : From 10 ms to 4s , From 10 ms to 7s for magnification technique
Automatic Exposure Control
  • Automatic exposure control (AEC): Microprocessor controlled, transparency compensation
  • Detectors: Semi conductor detector
  • Accuracy of optical density (2-6 cm): ± 0.15 OD from the mean optical density for predefined film screen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kV).
  • Density correction : ± 3 exposure points, adjustable in 1/8 step increments
  • Film-screen combinations : 2; User selectable on the generator control panel (H/D)
X-Ray Stand
  • Height adjustment: Motorized, 650 mm to 1350 mm floor to object table (in all angles)
  • Swivel range: +135° / -180°
  • Rotation of swivel arm: Motorized, isocentric
  • Source to Image Distance (SID): 65 cm
  • Film formats: 18cm x 24cm, 24cm x 30cm (15 mm thick Mammography cassettes according to DIN 6832/IEC 406). Automatic collimation to film format
  • Grid: Reciprocating; Pb 4/27 (4:1 ratio, 27 lines/cm)
  • Compression device: Opcomp, motorized compression initiated via footswitch or manual adjustment
  • Compression force: Maximum motorized force 200N
  • Magnification technique: Factor of 1.5 and 1.8
  • Power supply: 110V, 208V, 230V, 240V, 277V, ± 10%, 1-phase; 208V, 230V, 277V, 400V ± 10%, 2-phase; 50 Hz or 60 Hz
  • Fuse: 35A at 110V, 20A at 208V to 400V

Siemens Mammomat 1000 Nova

Generator
  • High-voltage wave form: Multipulse
  • Exposure voltage : 23kV to 35kV, adjustable in increments of 1kV
  • mAs range : Mo X-ray tube: 2mAs to 560 mAs (mAs-mode)up to 600mAs (AEC-mode)
  • Mo/W X-ray tube : 2mAs to 710 mAs (mAs-mode) up to 752 mAs (AEC-mode)
  • Exposure times : From 10 ms to 4s , From 10 ms to 7s for magnification technique
Automatic Exposure Control
  • Automatic exposure control (AEC): Microprocessor controlled, transparency compensation
  • Detectors: Semi conductor detector
  • Accuracy of optical density (2-6 cm): ± 0.15 OD from the mean optical density for predefined film screen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kV).
  • Density correction : ± 3 exposure points, adjustable in 1/8 step increments
  • Film-screen combinations : 2; User selectable on the generator control panel (H/D)
X-Ray Stand
  • Height adjustment: Motorized, 650 mm to 1350 mm floor to object table (in all angles)
  • Swivel range: +135° / -180°
  • Rotation of swivel arm: Motorized, isocentric
  • Source to Image Distance (SID): 65 cm
  • Film formats: 18cm x 24cm, 24cm x 30cm (15 mm thick Mammography cassettes according to DIN 6832/IEC 406). Automatic collimation to film format
  • Grid: Reciprocating; Pb 4/27 (4:1 ratio, 27 lines/cm)
  • Compression device: Opcomp, motorized compression initiated via footswitch or manual adjustment
  • Compression force: Maximum motorized force 200N
  • Magnification technique: Factor of 1.5 and 1.8
  • Power supply: 110V, 208V, 230V, 240V, 277V, ± 10%, 1-phase; 208V, 230V, 277V, 400V ± 10%, 2-phase; 50 Hz or 60 Hz
  • Fuse: 35A at 110V, 20A at 208V to 400V